Is the DT466 IDM relay circuit low voltage?

Is the DT466 IDM relay circuit low voltage?

2007 International 4300 dt466 IDM Relay circuit low voltage, no start. fuse 25amp at battery. 3rd visit for this issue. Hello I have a 2008 international 4300 ***************** With the non max force dt 466 . I am getting codes for IDM 534 idm relay voltage low 525 idm … read more

What is the code for 2007 International 4300?

2007 INTERNATIONAL 4300 CODE 128 155 7 CHECK ALL FUSES AT BATTERY ALL GOOD CONNECTIONS GOOD. DO YOU HAVE WIREING … read more Vocational, Technical or Tra…

Where is the starter on a 2004 DT466?

If you start from behind the head and start feeling downwards and onto the bell housing you will see that it is mounted with one small bolt at about the 11 o’clock position . It is above the starter by about 12 inches for sure but right on top of the bell housing .

Where are the fuses on an International DT IDM?

There are fuses in there on top of the batteries for the IDM and ECM. wires all the way up to the ecm and check the wiring carefully for rubout or corrosion anywhere. 05 International DT started up and then died. There are fuses in there on top of the batteries for the IDM and ECM.

What happens if IH blows IDM fuse at Battery?

IH with dt blows idm fuse at battery on schematron.org cranks but won’t start because of blown idm fuse at battery. vin# XXXXX I need a scematic to see what is all on this circuit and the idm module location. Somewhere between the IDM relay and the fuse the wire off pin 87 will splice into 2 circuits.

Is the IDM on my DTC 525 bad?

It doesnt show symptoms of a fault but it has the engine light on. It turns on and runs fine. I have checked the voltage to the IDM relay and its getting 12.4. I believe next i have to check the power getting to the IDM itself before concluding the IDM is bad but I need help on this one if anyone can give me any ideas.

How to program IDM for DT466 international?

Hi, any ideas for how to program IDM on DT466 international, deal won’t do it unless buy part from them which selling me at $1500, and I got from Ebay at $300 already, I have software MD32 DLC ( Diamond Logic Controller) which has program on menu, does it works? Thanks

What is fault code 525 FMI 6 injector dirver?

I have a truck with fault codes 525 fmi 6 Injector Dirver Circuit Fault *m* and 534 fmi 4 IDM- Relay Voltage Low. It doesnt show symptoms of a fault but it has the engine light on. It turns on and runs fine. I have checked the voltage to the IDM relay and its getting 12.4.

Is there an IDM relay on a 2007 International 4300?

I HAVE A 2007 INTERNATIONAL 4300, LOOKING FOR IDM RELAY LOCATION, I HAVE A 2007 INTERNATIONAL 4300, LOOKING FOR IDM RELAY LOCATION, – Answered by a verified Technician

Why is the IDM on my 4300 not working?

On 4300 models the box is prone to corroded contacts often causing no starts. This one was clean and all voltages were getting through. Now it was time to really look close at the rest of the IDM circuit. The wires that feed the IDM and ECM relays are wrapped in fabric tape and run along with the battery cables.

What is the serial number on a 2005 International 4300?

I have a 2005 International 4300 with code 534 fmi 4 sid 221 and code 525 fmi 6 sid 254. I have power at the fuses in Have truck repair questions?