What is the alarm code on a Thermo King?

What is the alarm code on a Thermo King?

On multi-temp units, the zone will be identified. Please record all alarms that occur to assist technician in resolving issue. Alarm codes with parenthesis (XX) may exist with alarm code 84 and may clear automatically. Operator Action: No action required. Operator Action: Manually monitor temperature.

Are there any warranties for the Thermo King sb-230?

This manual is published for informational purposes only. Thermo King Corporation makes no representations or warranties, express or implied, with respect to the information, recommendations and descriptions contained in this manual and such information, recommendations and descriptions

What kind of liability does Thermo King have?

Thermo King Corporation and its affiliates shall have no liability in contract or tort (including negligence and/or strict liability) or otherwise, to any person or entity for any personal injury, property damage or any other direct, indirect, special or consequential damage or liability whatsoever, arising out of or

What does TK monitor do on Thermo King TriPac?

Discussion:Thermo King TriPac EVOLUTION units have TK Monitor communication software built into the Base Controller of each unit. It allowed PC type computers to establish two way communications with the EVOLUTION control system without special software being loaded on the computer.

When did Thermo King release TriPac Evolution software?

In 2015 Thermo King developed the first EVOLUTION Service Tool. In 2016 TriPac EVOLUTION software Version 1.7 was released. They were to re-establish communication with Microsoft Windows 10 through Version 1511. When Windows 10 Version 1607 was released communication issues with TK Monitor returned.

Why is the screen on my thermostat blank?

A blank screen can be a normal case in some situations. If you go through the blank screen when your thermostat is wired into the electrical system of your home, the reason is related to the unit. You should guess that no power is reaching the unit.

Why does my Thermo King Battery not cycle?

Answer: The most common cause for a unit not to cycle has to do with charging. Check the amp meter in your gauge menu if it is above 5 amps the unit will not shut off. If this is true your battery may be starting to fail.

Where is the HPCO switch on a Thermo King?

Check for a defective high-pressure cutout (HPCO) switch. The HPCO is located on the top of the compressor. Disconnect the harness and bypass the HPCO switch. If the unit starts, then the HPCO switch is defective. Check the wiring harness on the 8D circuit. If the unit still won’t start, then verify voltage to the HPCO switch.

Where is the fuel solenoid on a Thermo King?

The fuel solenoid is located on the back of the injection pump. Turn the unit on and keep a finger on the solenoid. The unit will buzz, indicating a startup. The fuel solenoid will clunk, and the starter will engage. If the solenoid clunks, then it has energized and is okay.

When to report high discharge pressure on Thermo King truck?

09* High Evaporator Temperature If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day. 10* High Discharge Pressure (or Temperature) If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.

What to do if your Thermo King battery goes bad?

Jump the starter and observe the battery voltage. If the starter fails to engage and the voltage falls to 1V or 0V, then you have a bad battery. Replace the battery. Warning: Any attempt to jump start the battery may cause it to explode. Check for a defective high-pressure cutout (HPCO) switch. The HPCO is located on the top of the compressor.