How do I fix f02 error code APC?

How do I fix f02 error code APC?

BACK UPS pro 1500 error ode f02 after shutdown for the night,…

  1. just power off your APC.
  2. just remove the power cord from sector, keep battery.
  3. press constantly power button until you hear the second beep signal.
  4. Let the apc restart, it will mark f02 error again.
  5. plug the power cord.
  6. restart the APC.

How do you troubleshoot a bad UPS?

Be sure that the power cable is securely connected to the unit and to the utility power supply. The input circuit breaker has tripped. Reduce the load to the UPS, disconnect nonessential equipment and reset the circuit breaker. Check the utility power supply to the UPS by plugging in a table lamp.

How do I reset my APC Pro 1000?

APC Smart UPS – How to reset / restart

  1. Turn off and unplug UPS from wall.
  2. Press and hold the OFF button again.
  3. You may see a quick flash of the LED’s and you should hear an audible “”click”” from the UPS.
  4. Turn UPS back on.

What does F04 mean on a battery charger?

F04 OVERTIME CONDITION – Battery will not accept a charge after 18 hours of continuous charging. Battery may have internal damage. Have battery chacked by certified auto service center. BATTERY CHARGE RATE IS SET TOO LOW – Set charger to higher charge rate.

What causes UPS to fail?

A common, and highly avoidable cause of UPS failure is temperature. A UPS will become less effective if you use or store it in an area that is warmer than 77°F. Shockingly, a 15° increase will cut your battery’s expected life in half, so it is critical to use proper ventilation. Improper use of the battery.

How do I reset my APC backups Pro 1500?

Try resetting the unit: safely power down your attached load, turn the UPS off, and disconnect everything from it. Then unplug it from the wall. Open the battery door and remove the battery pack. With the battery pack removed and the unit still unplugged, press and hold the power button for a second or two.

How do I test APC Smart UPS 1000?

To manually start a Self Test from the UPS:

  1. LCD Screen Models: Go to the “Test & Diags” menu, then select “Self Test”
  2. Legacy Models (No LCD Screen): Press and hold the “I/Test” button. After several seconds the UPS will switch to battery. You can then release the button and the test will continue to completion.

What does APC ups F04 mean on APC pro 1300?

APC UPS F04 Error, Is It Dead? Get answers from your peers along with millions of IT pros who visit Spiceworks. I have a APC Back UPS Pro 1300. Recently in the past two weeks about every day it throws code F04 meaning clamp short. It shuts down everything.

Why does my APC back-ups product be beeping?

Therefore, in order to provide proactive warnings of changing UPS and power conditions to users, APC’s UPSs have audible tones. An occasional single beep from the UPS is normal UPS operations. This means that the UPS is protecting the load.

When do I need to replace my APC battery?

If the battery fails the self-test, the “”Replace Battery”” LED will illuminate. The Replace Battery LED is a WARNING that the battery may be near the end of its life, and replacement is typically recommended within 2-4 weeks.