Where is the reset button on a Thermo King?

Where is the reset button on a Thermo King?

What model TriPac do you have? The older style had a reset button on the side of a vertical box which was usually in the passenger side box. The newer Evolution model does not have that button, resets are done by turning the unit off and on at the control panel.

How do I fix code 20 on a Thermo King?

Thermo King Alarm Code 20: Engine Failed to Start

  1. Check the inline fuel filter, located in the transfer pump inlet hose fitting.
  2. Remove the bolt and washers.
  3. Remove the filter from inside the bolt and check for debris clogging the screen.
  4. Clean out the bolt, the screen, and the banjo fitting.

What does code 21 on Thermo King Reefer mean?

well I use to be a ref tech and code 21 is low Freon aka check cooling system. From the sounds of it your system has a Freon leak and is out of Freon that’s why the temp is going up and it is showing ETV system because according to the computer your unit should be at certain temp by now and its not getting there so it throws that code also.

What is the alarm code on a Thermo King?

On multi-temp units, the zone will be identified. Please record all alarms that occur to assist technician in resolving issue. Alarm codes with parenthesis (XX) may exist with alarm code 84 and may clear automatically. Operator Action: No action required. Operator Action: Manually monitor temperature.

When to report high discharge pressure on Thermo King truck?

09* High Evaporator Temperature If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day. 10* High Discharge Pressure (or Temperature) If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.

How to fix a leak on a Thermo King Reefer?

Depending on where the leak is depends on how much it costs to fix. Also pray its not a compressor seal then tech has to take out the compressor and install another seal, add oil to compressor then leak check and vacuum and recharge.